Vet Injection & Infusion
Three-Way Stopcock Set
- Ports: 3, luer lock
- Tube: short extension
- Tap: 90 degree positions
- Use: single use
- Product description: Three-way stopcock with a short extension tube and male luer lock, 90 degree tap positions with a flat bar handle for reading position at a glance.
A three-way stopcock looks like a trivial piece of plastic until a patient is on three infusions and one of them has to be given as a bolus without stopping the others. Then the difference between a stopcock that turns cleanly and one that seizes is the difference between a calm procedure and a line that has to be replaced under a struggling patient.
These are three-way stopcocks with a short extension tube and a male luer lock at the patient end. The tap turns through 90 degree positions with a positive click, and the handle is a flat bar that shows its position from across the table - which matters when the person turning it is wearing gloves and looking at a monitor rather than at the tap.
Reading the tap
The bar points along the open path. With the bar in line with a port, flow runs between the other two; with the bar at right angles to a port, that port is closed. Every stopcock works this way, and every stopcock error is the same error: assuming the bar points at the port that is open. Check with the fluid, not with the handle, until the logic is automatic.
Why the extension
The short tube takes the tap away from the catheter hub, so a bolus can be given without levering on the catheter, and so the tap can be taped to the limb rather than hanging free. A tap hanging on a catheter hub is a tap that works the catheter loose every time it is turned.
In practice
Three ports means three things at once: a maintenance fluid, a drug line, and a flush or a second drug. Label the ports - a strip of tape with a letter on each is enough - because the failure mode with a stopcock is not the device, it is giving a drug into the line that was running the other drug. Keep one port capped when it is not in use; an open port is an air inlet, and a small patient does not tolerate air.
| Parameter | Value |
|---|---|
| Type | Three-way stopcock with extension tube |
| Ports | 3, luer lock; male luer lock at patient end |
| Tap | 90 degree positions, flat bar handle |
| Tube | Short extension, kink-resistant |
| Use | Single use |
| Application | Multi-drug infusion, bolus administration, blood sampling from a line |
Ordering
Supplied individually or in boxes for the practice that uses them on every hospitalised patient. If you run infusions through a syringe driver as well as a gravity line, tell us and we will confirm the fittings so the tap sits between them without an adaptor - every adaptor in a line is a joint that can come apart.