  • Flexible Positioning Arm
Flexible Positioning Arm

Flexible Positioning Arm

  • Type: segmented flexible arm
  • Base: magnetic, stainless tables
  • Tip: radio-opaque steel ball
  • Use: radiographic positioning
  • Product description: Segmented flexible arm on a magnetic base with a stainless radio-opaque ball at the tip, for holding limbs and heads in position during radiography.
  • INQUIRY

Positioning is the part of radiography that decides whether the film is diagnostic. A cat with a rotated pelvis or a dog with an elbow held at the wrong angle will produce a film that has to be repeated, and repeating means another anaesthetic or another dose. What is needed is something that holds a limb or a head where it was put, without a person's hand in the primary beam.

This is a flexible arm on a magnetic base with a stainless ball at the working end. The arm is a segmented gooseneck: bend it where you want the bend and it stays, which means one hand can position a limb and the other can work the machine. The base is magnetic, so it sits on a stainless table without clamps or tape.

The ball is the point

The ball at the end is radio-opaque and spherical. On the film it appears as a perfect circle regardless of the angle it was positioned from, which makes it a reference point: place it against the skin at the level of the structure you are measuring, and the magnification between the structure and the film can be worked out from the ball's known diameter. It also works as a skin reference for a swelling or a foreign body, because a sphere has no orientation to misread.

Where it earns its place

Holding a forelimb in extension for a lateral elbow, holding a head in position for a dental series, holding a jaw open while an intraoral film is placed, and holding a limb out of the way of a thorax. In each case the alternative is an assistant's hand, and a hand in the beam is a hand that receives dose.

Setting it up

Clean the table surface before the base goes down; a magnetic base on a layer of hair and dust holds less well than one on bare steel. Do not force the segments past their limit - a gooseneck bent hard against a stop work-hardens and eventually breaks at that joint. Keep the arm out of the primary beam where possible: it is radio-opaque, and while the ball is meant to be seen, the arm itself is an artefact across the image.

ParameterValue
TypeFlexible segmented arm, magnetic base
Working endStainless steel ball, radio-opaque
BaseMagnetic, for stainless table tops
ArmMoulded segments, holds position without locking screws
Ball diameterConfirmed per model - state the size you need for your measuring protocol
CleaningWipe with alcohol; not for autoclave
ApplicationRadiographic positioning, jaw support, limb restraint during imaging

Two sizes, one choice

The arms are supplied in different lengths and ball diameters. A short arm with a small ball suits intraoral and dental work where space is tight; a long arm with a larger ball is for limbs and for thoracic positioning. Tell us what you image most and we will match the length to the table and the cassette size you use.

The base will not hold on an aluminium or composite table. If your imaging table is not stainless, say so and we will quote a clamp base instead.