[email protected]

Home   |   Vet Surgery Tables & OR Furniture

Vet Surgery Tables & OR Furniture

  • Hydraulic Surgical Table
Hydraulic Surgical Table

Hydraulic Surgical Table

  • Top: 304 stainless, slatted drain
  • Lift: hydraulic, foot pedal
  • Base: single column, water reservoir
  • Supplied: IV pole, tray, pedal
  • Product description: Single-column hydraulic veterinary surgical table with slatted 304 stainless drain top, foot pedal lift, IV pole, instrument tray and base water reservoir. For small animal surgery and dental procedur
  • INQUIRY

A surgical table for small animal work has to do three things at once: put the patient at a height the surgeon can hold for an hour, let irrigation and blood leave the surface instead of pooling under the animal, and keep the instruments and the drip line inside reach without a second trolley in the way.

This is a single-column hydraulic table built around those three points. The top is a slatted 304 stainless surface, so fluid runs straight through the grid and into the base tray rather than spreading under the patient. The column is raised and lowered by a hydraulic ram driven from a foot pedal, which leaves both hands free to hold the patient and the light handle. The base housing carries the pump and a water reservoir, so the table stands on its own footprint and does not need a separate cart for the irrigant.

Why the slatted top matters more than it looks

Fluid on a flat table top conducts heat away from the patient and turns a sterile field into a wet one. In a dental or wound procedure where the lavage volume is high, the animal ends up lying in a pool at body temperature, and the drape wicks it upward. A slatted surface removes the fluid at the point it lands. It also gives you somewhere to tie a limb without a separate tie-down bar, because the grid accepts a tape anywhere along its length.

Hydraulic lift, foot controlled

The lift runs on a hydraulic ram rather than a mechanical crank or an electric scissor. That means no motor to fail in a wet room, no control box to keep off the floor, and a descent that can be feathered rather than dropped. The pedal is on a coiled lead long enough to be moved to the side the surgeon works from. Load capacity is stated by the factory and confirmed on the quotation; for a table of this footprint it covers the large canine range with a drape and instrument load on top.

What comes with the table

  • IV pole with double hook - fits the socket at the head end, height adjustable, holds a 500 ml or 1 L bag plus a second line
  • Stainless instrument tray - cantilever arm, swings over the table and locks; deep enough for a basic kit, removable for cleaning
  • Slatted drain top - 304 stainless, grid spacing wide enough to pass hair and clot without blocking
  • Base tray and reservoir - collects what comes through the grid; drain connection at the base
  • Foot pedal - coiled lead, waterproof housing
ParameterValue
Table top304 stainless steel, slatted drain surface
Top sizeStandard small animal size, confirmed on order
LiftHydraulic, foot pedal control
BaseSingle column, stainless housing with water reservoir
Supplied withIV pole, instrument tray, foot pedal, drain
Load capacityStated per unit, confirmed on quotation

Setting it up and keeping it working

Put the table where the pedal lead reaches both sides of the working position, and leave access to the base housing because the reservoir needs emptying between cases. Check the ram for creep once a month: a table that sinks under load has air in the system or a worn seal, and both get worse slowly until the table drops mid-procedure. Wipe the grid down with a chlorinated detergent after each case and flush the base tray, because clot left in the drain line sets and blocks it.

The column and base are stainless but the ram and pedal are not, so do not hose the underside. Keep the pedal out of the wet zone when the table is being cleaned.

Options

Side rails, a waste bucket, a flat non-slatted top and an electric lift version are all available on the same platform. Tell us the procedures you do most and we will quote the configuration that fits; if you need a specific top size for a cage bank or a theatre layout, send the dimensions and we will confirm what the factory can build.