[email protected]

Home   |   Imaging & Digital Dentistry

Imaging & Digital Dentistry

X-Ray Tube Head Adapter for Positioners

  • Function: Head to ring adapter
  • Fit: Adjustable, multi-diameter
  • Mount: Tool-free
  • Use: With aiming rings
  • Product description: Adapter that bridges the gap between the tube head and the positioning ring so one ring set fits different cone diameters.
  • INQUIRY

A positioning ring only works if the cone actually sits in it. In practice the cone is a different diameter on every unit, and the ring is a fixed size, so the ring either drops over the cone with play or will not go on at all. The result is the same: the operator holds the head by hand and the geometry is lost.

This adapter sits between the two. It clamps to the tube head and presents a surface the ring seats against, so the ring is centred on the cone regardless of which unit it is being used with.

What it solves

  • Ring sets that do not fit the cone diameter on a given X-ray unit.
  • Play between ring and cone that lets the head move between positioning and exposure.
  • Mixed equipment lists, where one practice or one dealer supports several X-ray brands.
  • Retrofitting a positioning system to an older unit without changing the tube head.

Design points

FeatureDetail
AdjustmentMulti-diameter clamping, fits a range of cone sizes
FixationRigid, no free play once set
InstallationTool-free, no calibration of the unit required
CompatibilityUsed with standard aiming rings

The rigid connection is the point. A friction fit that feels tight when you install it can creep under the weight of the arm, and a millimetre of creep at the cone becomes a visible angulation error at the sensor.

Installing it

  • Clean the cone surface before fitting; a dusty cone lets the adapter rotate under load.
  • Tighten the clamping screws evenly, alternating sides rather than driving one screw fully home.
  • Fit the ring and check it is concentric with the cone by eye from the patient side before the first exposure.
  • Re-check tightness weekly. Adapters are knocked, not worn out.

Before you order

Send us the X-ray unit model and the outer diameter of the cone at the point where the ring would sit. Cone profiles taper, so the diameter at the tip and the diameter 30 mm back are different numbers, and the adapter has to grip the second one.

The adapter is supplied on its own; rings and positioners are separate items, so a practice already running a ring system can add the adapter without replacing the rest.