  • LED Surgical Light, Twin Head
LED Surgical Light, Twin Head

LED Surgical Light, Twin Head

  • Heads: twin, 700 mm and 500 mm
  • Illuminance: up to 160,000 lux
  • Colour temp: 3500 - 5000 K, 6 steps
  • Source: LED, 60,000 hours
  • Product description: Ceiling-mounted twin-head LED surgical light with 700 mm and 500 mm heads, 160,000 lux, colour temperature 3500-5000 K in six steps and integrated camera option.
  • INQUIRY

A surgical light is judged by one thing: whether the surgeon can see into the cavity without their own head casting a shadow into it. Everything else - the number of LEDs, the colour temperature steps, the camera - is secondary to that.

This is a ceiling-mounted twin-head LED light. The two heads are carried on articulated arms from a single ceiling column, so one head can be brought over the surgeon's shoulder and the other over the assistant's, and the light arrives at the wound from two directions rather than one. That is what removes the shadow of a hand or an instrument: not a brighter single source, but a second source at a different angle.

The head

Each head is a petal-pattern array of LED modules behind a lens, with a central sterile handle for positioning. The petal arrangement is what produces a beam that stays even as the head is tilted - a single-ring array throws a bright centre and a dim edge, and the edge is where the wound extends to when the retractor goes in. Illuminance at the centre reaches 160,000 lux on the larger head.

Colour temperature, six steps

The light runs from 3500 K to 5000 K in six steps. This is not a cosmetic feature. At the warm end, tissue colour reads closer to how it looks under operating-theatre ambient light and bleeding is easier to judge against surrounding tissue; at the cool end, the field looks whiter and the contrast between structures is higher, which is what you want for fine work in a deep cavity. Most surgeons settle on one setting and stay there, but the setting is worth choosing deliberately rather than accepting the factory default.

LED life

The modules are rated at 60,000 hours, which at a realistic duty cycle is well beyond the working life of the rest of the fitting. There is no bulb to change, no colour shift from a lamp ageing, and no hot spot on the surgeon's neck from an incandescent housing.

ParameterValue
ConfigurationTwin head, ceiling mounted, articulated arms
Head sizes700 mm and 500 mm, in twin-700 or 700/500 combinations
IlluminanceUp to 160,000 lux at the centre of the field
Colour temperature3500 - 5000 K, six steps
SourceLED modules, rated 60,000 hours
HandleCentral sterile handle, removable
OptionsIntegrated camera with monitor; mobile stand version

Ceiling and mounting

The ceiling must carry the load of the column and both arms, and the fixing point has to be chosen with the table position in mind rather than with the room's symmetry. Send us the ceiling type - concrete slab, suspended grid, or a retrofit into an existing structure - and the table position, and we will confirm the mounting arrangement. A light fixed over the middle of the room rather than over the table is the most common installation mistake and the most expensive to correct.

Mobile version

Where the ceiling cannot take a fixing, the same heads are available on a mobile stand. The trade-off is that a stand has to be moved and locked, and a locked stand in a small room is one more thing between the surgeon and the trolley - but for a clinic that rents its premises, it is the only option that does not require landlord consent.