Laparoscopic Clip Applier

  • Shaft: rotating, 5 mm / 10 mm
  • Handle: pistol grip with ratchet
  • Clips: polymer or titanium
  • Sterility: supplied sterile, single use
  • Product description: Single-use laparoscopic clip applier with rotating shaft, ratcheted pistol grip and jaw closure indicator. 5 mm and 10 mm shafts; polymer or titanium clips.
  • INQUIRY

A clip applier is the instrument that makes laparoscopic sterilisation and pedicle ligation quick: a polymer or titanium clip is pushed across a vessel, the vessel is occluded, and nothing is left in the abdomen except the clip. The alternative is a ligature tied intracorporeally, which takes longer and needs two instruments in the port at once.

This is a single-use laparoscopic clip applier with a rotating shaft, a ratcheted handle and a jaw that loads and crimps one clip at a time. The shaft rotates through a full turn on a collar behind the handle so the jaw can be brought square to a pedicle that is not where the port is, and the handle ratchet gives the surgeon feedback that the clip has been closed rather than squeezed.

What makes the difference in use

The jaw has to hold the clip square while it is being closed. A jaw that has play will tilt the clip, and a tilted clip on an ovarian pedicle is a clip that slides off in recovery. The second thing is the shaft diameter: a 5 mm shaft passes through a standard small animal port and can be used alongside a scope without fighting for room, while a 10 mm instrument is for larger patients and larger vessels.

Clip choice

Polymer clips are radiolucent and do not interfere with imaging, and they hold well on tissue that would cut through a thin metal clip. Titanium clips are thinner, appose more tightly on a fibrotic pedicle, and are visible on radiographs. Which one you use matters less than matching the clip size to the instrument and the vessel: a clip that is too small will not close across the vessel, and one that is too large will not grip it.

ParameterValue
TypeLaparoscopic clip applier, single use
ShaftRotating, 5 mm and 10 mm options
HandlePistol grip with ratchet, jaw closure indicator
ClipsPolymer and titanium, sizes confirmed on order
SterilitySupplied sterile, single use
ApplicationOvariectomy, pedicle ligation, cryptorchid vessel control

Technique points

Load the clip with the jaw open and the vessel centred, then close on the vessel rather than pushing the applier forward onto it; pushing drags the pedicle and the clip lands at an angle. Leave a cuff of tissue beyond the clip before dividing, and place two clips on the patient side of a pedicle you are about to cut. Check the tip of the jaw is clear of the scope before closing, because a clip crimped onto the scope lens is an expensive way to learn that lesson.

Count clips. A clip that has been fired and not seen to land is somewhere in the abdomen, and a lost clip is a second look rather than a guess.

Buying

Appliers are supplied singly or in boxes, with clips ordered separately in the size that matches the instrument. Tell us the port size you work through and the vessel sizes you are clipping, and we will confirm the shaft and clip size before the order ships.