Medical
ENT Powder Insufflator
- Type: bulb operated, manual air
- Reservoir: glass bottle, screw-on
- Nozzle: curved metal, interchangeable
- Autoclave: nozzle and cap 134 C
- Product description: Bulb-operated ENT powder insufflator with glass reservoir and curved metal nozzle, for delivering powdered preparation to the throat and larynx.
Powder and liquid do not travel the same way. A spray gun draws liquid up a tube and breaks it into droplets in an airstream. A powder insufflator cannot do that, because powder does not climb a tube and will not pass a venturi. It has to be carried: lifted off the surface of the powder by a moving airstream and blown out through a nozzle before it has time to settle.
This is a bulb-operated insufflator - rubber bulb, glass reservoir, curved metal nozzle. Squeezing the bulb pushes a pulse of air across the mouth of the reservoir, powder is picked up and carried out through the nozzle, and the operator repeats until enough has been delivered.
Why a bulb rather than compressed air
A bulb gives a short, low-volume pulse, and that is the right shape for powder. A continuous blast empties the reservoir into the room; a pulse lays a cloud where the nozzle is pointed. It also means the insufflator needs no connection to the unit - it works at the chair, at the bedside, or in a room with no piped air at all.
The cost is repeatability. A bulb delivers what the hand delivers, and two operators squeezing the same bulb do not deliver the same amount. Where the dose matters that is a real limitation; where the powder is applied to effect - until the surface is coated - it does not, because the endpoint is visible.
The reservoir
Glass, because powder is abrasive and because glass can be washed and boiled. A plastic reservoir clouds with use, and the clouding hides the powder level, which is the one thing the operator needs to see. Keep the reservoir dry: powder that has taken up moisture from the air clumps, and clumped powder comes out in lumps or not at all.
The nozzle
Curved, so the tip can pass over the tongue and point at the pharynx or larynx without the hand blocking the view. The bore is wider than a spray nozzle's, because powder bridges across a small opening - a bore that would be fine for liquid blocks on the first use with powder. Nozzles are removable for cleaning and are available separately.
Cleaning
Disassemble after every use: nozzle off, reservoir off, powder path brushed out before the residue sets. Warm water and a soft brush, then dry completely before reassembly. Do not autoclave the bulb - rubber that has been autoclaved hardens and perishes, and a perished bulb delivers a weak pulse that reads as a blocked nozzle and sends the operator looking in the wrong place.
The metal nozzle and the reservoir cap take 134 C.
Insufflator or spray gun
The choice is made by the preparation, not by preference. Powder for a surface that is dry or has to stay dry; liquid where the agent has to reach into a crevice or coat a mucosal surface evenly. A spray gun cannot deliver powder, and an insufflator cannot deliver liquid - liquid in the reservoir is blown out as a jet, not a mist.
| Parameter | Value |
|---|---|
| Type | Bulb operated, manual air |
| Reservoir | Glass bottle, screw-on |
| Nozzle | Curved metal, interchangeable |
| Bulb | Rubber, replaceable |
| Autoclave | Nozzle and cap 134 C; bulb not autoclavable |
| Packing | 1 set, spare nozzles available |
Before ordering
Say whether the nozzle has to reach the pharynx or further, and whether the reservoir is to be boiled or chemically disinfected, and the nozzle length and reservoir type are confirmed against both. Spare nozzles and spare bulbs are available separately - both are consumables, and both fail at the least convenient moment.
Categories
Latest News
Contact Us
Contact: Mario
Phone: +8613482534556
Tel: +86-574-62913789