Dental Electrosurgery Unit ATS-S1, 40W with 9 Electrodes
- ATS-S1
- 40 W ±10%
- 110 / 220 V, 50/60 Hz
- 9 electrodes, autoclavable handpiece
- Product description: 40 W dental electrosurgery unit for soft tissue incision and coagulation. Nine electrodes, single-dial power control, 110/220 V, autoclavable handpiece. Gingivectomy, crown lengthening, frenectomy and
A scalpel cuts cleanly but leaves a bleeding field. A laser cuts cleanly but costs five figures and needs plume extraction. Electrosurgery sits in the middle: it cuts and coagulates with the same tip, needs no sutures on most soft tissue, and a hygienist can be trained on it in an afternoon. That is why it ends up doing gingivectomies, crown lengthening and implant exposure in practices that never bought a laser.
The ATS-S1 is a 40 W high-frequency unit with a single rotary dial for power. One control is the whole interface — there is no mode selector to get wrong, and no menu to lose a setting in. Power runs from 1 to 10, and the manufacturer publishes which setting and which electrode to use for each procedure, which is the part most units leave the clinician to work out by trial.
Nine electrodes, and what each one is for
The tip decides the result more than the power setting does. The set covers three families: fine loop and needle electrodes for incision, ball electrodes for coagulation, and shaping electrodes for contouring.
| Code | Type | Tip | Used for |
|---|---|---|---|
| C30C | Incision | Ø 0.30 mm | Fine gingival incisions, thin tissue |
| C30S | Incision | Ø 0.40 mm | General incision, sulcus widening |
| C40C | Incision | Heavier gauge | Resection of thicker soft tissue |
| C40S | Incision | Heavier gauge | Flap and tissue resection |
| EC10N | Incision + coagulation | Ø 1.00 mm | Cut with simultaneous haemostasis |
| EC25B | Coagulation | Ø 2.50 mm ball | Surface coagulation without cutting |
| EX22R | Shaping | Ø 0.22 mm | Contouring, troughing |
| EX22T | Shaping | Ø 0.22 mm | Gingival reshaping, flat contour |
| EX22L | Shaping | Ø 0.22 mm | Access in tight or posterior sites |
Clinical applications published by the manufacturer
The unit is specified across five areas rather than as a single-purpose tool, and the electrode number changes with each one. A few of the indications:
| Area | Procedure | Power |
|---|---|---|
| Oral surgery | Gingivectomy | 4–6 |
| Oral surgery | Abscess incision and drainage | 5–6 |
| Oral surgery | Frenuloplasty | 5–6.5 |
| Restorative | Crown lengthening | 4–5 |
| Restorative | Gingival hyperplasia removal | 4–5 |
| Restorative | Widening the gingival sulcus | 3.5–5 |
| orthodontics | Crown lengthening to place brackets | 4–5 |
| Implant | Second and third stage gingival circumcision | 3–5 |
| Implant | Gingivoplasty | 5–6 |
| Periodontal | Flap surgery, gingivectomy, gingivoplasty | 3–5 |
What ships in the box
Main unit, nine electrodes in a box, autoclavable handpiece with cord, wired footswitch, grounded power cable, two silicone pads for the handpiece, a neutral electrode bracelet, handpiece stand, manual, quick guide, warranty card and packing list. The handpiece detaches and takes standard high-temperature, high-pressure sterilisation, and the electrodes are sheathed so only the active tip contacts tissue.
Technical specifications
| Parameter | Value |
|---|---|
| Model | ATS-S1 |
| Supply voltage | 110 / 220 V, 50/60 Hz |
| Max power output | 40 W ±10% |
| Main unit dimensions | 21 × 18 × 8 cm |
| Main unit weight | 1.3 kg |
| Net weight / gross weight | 1.85 kg / 2.5 kg |
| Package dimensions | 25.5 × 24.1 × 18.5 cm |
| Electrodes supplied | 9 types, 9 pcs per box |
Before you order
Two things to check, because they decide whether the unit is usable in your market. First, the plug and voltage: the factory builds 110 V and 220 V versions, so state the destination country rather than assuming. Second, registration — the unit is registered with the Chinese NMPA as a Class II device, and that registration is not recognised in the EU or the US. If you need CE marking under EU MDR or a 510(k), tell us before ordering and we will confirm what the factory can supply for your market instead of assuming it.
Consumables: electrodes are the recurring cost, and they are ordered separately from the unit. Tell us which procedures you do most and we will suggest the electrode mix rather than shipping nine of each.
Categories
- Endodontics
- Burs, Polishers & Abrasives
- Handpieces & Motors
- Restorative & Prosthodontics
- Imaging & Digital Dentistry
- Orthodontics
- Unit Parts & Accessories
- Dental Instruments
- Implant & Biomaterials
- Preventive & Whitening
- Infection Control & Disposables
- Dental Lab & Materials
- dental equipment
- Loupes & Accessories
Latest News
Contact Us
Contact: Mario
Phone: +8613482534556
Tel: +86-574-62913789
Add: No.33 West Road, Gaoqiao Town, Ningbo, Zhejiang, China