  • Dental Electrosurgery Unit ATS-S1, 40W with 9 Electrodes
Dental Electrosurgery Unit ATS-S1, 40W with 9 Electrodes

Dental Electrosurgery Unit ATS-S1, 40W with 9 Electrodes

  • ATS-S1
  • 40 W ±10%
  • 110 / 220 V, 50/60 Hz
  • 9 electrodes, autoclavable handpiece
  • Product description: 40 W dental electrosurgery unit for soft tissue incision and coagulation. Nine electrodes, single-dial power control, 110/220 V, autoclavable handpiece. Gingivectomy, crown lengthening, frenectomy and
  • INQUIRY

A scalpel cuts cleanly but leaves a bleeding field. A laser cuts cleanly but costs five figures and needs plume extraction. Electrosurgery sits in the middle: it cuts and coagulates with the same tip, needs no sutures on most soft tissue, and a hygienist can be trained on it in an afternoon. That is why it ends up doing gingivectomies, crown lengthening and implant exposure in practices that never bought a laser.

The ATS-S1 is a 40 W high-frequency unit with a single rotary dial for power. One control is the whole interface — there is no mode selector to get wrong, and no menu to lose a setting in. Power runs from 1 to 10, and the manufacturer publishes which setting and which electrode to use for each procedure, which is the part most units leave the clinician to work out by trial.

Nine electrodes, and what each one is for

The tip decides the result more than the power setting does. The set covers three families: fine loop and needle electrodes for incision, ball electrodes for coagulation, and shaping electrodes for contouring.

CodeTypeTipUsed for
C30CIncisionØ 0.30 mmFine gingival incisions, thin tissue
C30SIncisionØ 0.40 mmGeneral incision, sulcus widening
C40CIncisionHeavier gaugeResection of thicker soft tissue
C40SIncisionHeavier gaugeFlap and tissue resection
EC10NIncision + coagulationØ 1.00 mmCut with simultaneous haemostasis
EC25BCoagulationØ 2.50 mm ballSurface coagulation without cutting
EX22RShapingØ 0.22 mmContouring, troughing
EX22TShapingØ 0.22 mmGingival reshaping, flat contour
EX22LShapingØ 0.22 mmAccess in tight or posterior sites

Clinical applications published by the manufacturer

The unit is specified across five areas rather than as a single-purpose tool, and the electrode number changes with each one. A few of the indications:

AreaProcedurePower
Oral surgeryGingivectomy4–6
Oral surgeryAbscess incision and drainage5–6
Oral surgeryFrenuloplasty5–6.5
RestorativeCrown lengthening4–5
RestorativeGingival hyperplasia removal4–5
RestorativeWidening the gingival sulcus3.5–5
orthodonticsCrown lengthening to place brackets4–5
ImplantSecond and third stage gingival circumcision3–5
ImplantGingivoplasty5–6
PeriodontalFlap surgery, gingivectomy, gingivoplasty3–5

What ships in the box

Main unit, nine electrodes in a box, autoclavable handpiece with cord, wired footswitch, grounded power cable, two silicone pads for the handpiece, a neutral electrode bracelet, handpiece stand, manual, quick guide, warranty card and packing list. The handpiece detaches and takes standard high-temperature, high-pressure sterilisation, and the electrodes are sheathed so only the active tip contacts tissue.

Technical specifications

ParameterValue
ModelATS-S1
Supply voltage110 / 220 V, 50/60 Hz
Max power output40 W ±10%
Main unit dimensions21 × 18 × 8 cm
Main unit weight1.3 kg
Net weight / gross weight1.85 kg / 2.5 kg
Package dimensions25.5 × 24.1 × 18.5 cm
Electrodes supplied9 types, 9 pcs per box

Before you order

Two things to check, because they decide whether the unit is usable in your market. First, the plug and voltage: the factory builds 110 V and 220 V versions, so state the destination country rather than assuming. Second, registration — the unit is registered with the Chinese NMPA as a Class II device, and that registration is not recognised in the EU or the US. If you need CE marking under EU MDR or a 510(k), tell us before ordering and we will confirm what the factory can supply for your market instead of assuming it.

Consumables: electrodes are the recurring cost, and they are ordered separately from the unit. Tell us which procedures you do most and we will suggest the electrode mix rather than shipping nine of each.